Communications Operational FAQ
- Manual System Issues
- Automatic System Issues
- HME System Issues
- GreaseNode Issues
- Physical Issues
- Decision Trees
1. Manual System Issues
Issue Possible resolution(s) 1 can’t see head unit - or late last seen “event”
charging location in range of coms ?
gateway still plugged in to power ?
power still online onsite ? ( other devices have power ? )
2 HU wont sync - manual button
See HU FAQ
3 HU won't sync automatically
See HU FAQ
2. Automatic System Issues
Issue
Checks
Possible resolution
1 EP last seen “event” is very late
endpoint has power
gateway powered and online
E/P in range of com’s
check battery/replace
return gateway power and retry
7sec. button test for range
if no change - contact support@greaseboss.com.au
2 GW data gap (cumulative OK, no data)
Co9nfirm gateway is powered on
see EP issues (data gap)
see endpoint FAQ Endpoint Operational FAQ
3 NO FLOW EVENTS
is the rssi strength optimal between device and gateway ? ( optimal rssi strength > -75dba )
E/P in range of com’s
see endpoint FAQ Endpoint Operational FAQ
4 NO HEARTBEAT DATA
is the rssi strength optimal between device and gateway ? ( optimal rssi strength > -75dba )
E/P in range of com’s
see endpoint FAQ Endpoint Operational FAQ
5 NO DIAGNOSTICS DATA
is the rssi strength optimal between device and gateway ? ( optimal rssi strength > -75dba )
E/P in range of com’s
see endpoint FAQ Endpoint Operational FAQ
6 NO FLOW / HEARTBEAT / DIAGS
endpoint has power
gateway powered and online
E/P in range of com’s
see endpoint FAQ Endpoint Operational FAQ
3. HME Issues
Issue
Checks
Possible resolution
1 EP not reliably syncing
range
coms location
fauty GW
if all- sim? gateway itself online?
if one -see EP trouble shooter
see EP FAQ - Endpoint Operational FAQ
2 Not syncing often enough and missing issues
dignostic data appears too long between regular syncs
refine the selfsync time period
contact support@greaseboss.com.au with relevant serial number
4. GreaseNode Issues
Issue
Possible resolution
1
if no data is getting the the GB cloud then a GreaseNode site may have a local access issue
GB to confirm access issue and escalate to site IT for L3 resolution
5. Physical Issues
Issue
Checks
Possible resolution
1 damage
2 broken cable feed/pwr/data
3 antenna lost
4 Confirm device is being powered
see if a wifi connection is available named the same as gateways serail no# found on bottom of gateway ( EX: GBLG20001W )
5 suspected 4G inoperative
check if wifi available= powered ON
use RMS or other to validate connectivity (Support)
restart and retest - wait up to 10 mins for full startup
check if wifi available, request support GB
6 does the g/w connect to site specific coms (greaseNode scenario or site Lan/Wifi backhaul)
check if wifi available
Support check connectivity
check if wifi available, request support GB
request support site specific coms IT dept.
reboot/restart and recheck
Decision Trees
1. ENDPOINT NOT SEEN IN EXPECTED TIME
2. HEADUNIT NOT SEEN
3. SETTING UP YOUR GATEWAY